  • Crystaldex G25(中) Crystaldex G50.png.jpg
  • Crystaldex G25(1753864930315).png

Crystaldex G25


classification:Dextran gel packing

G25 dextran gel does not require swelling and can be used directly in columns. It has high desalting efficiency, high protein recovery rate, and is inexpensive, making it suitable for small-scale use in laboratories.

Product Overview

Gel filtration chromatography (also known as molecular sieving) works on the principle that small molecules can pass through the pores of a porous gel, while large molecules cannot. Additionally, the time it takes for molecules to pass through the gel pores varies depending on their molecular weight and geometric shape, thereby separating samples of different molecular weights and structures. Crystaldex G25 utilizes gel filtration to remove salts, labels, and other small molecules (MW < 5000 Da) from nucleic acids, proteins, and other large molecules, or for buffer exchange.

The finer the dextran G25 resin particles, the higher the resolution and separation efficiency, making it more suitable for separation experiments involving molecules with similar molecular weights; desalting and buffer exchange typically use medium-sized or coarse-sized resin particles.

Product Components

Product Name

Catalog No.

Packaging

Particle Size

Crystaldex G25

(Superfine)

C211001

100g

20-75µm

C211002

500g

C211003

5kg

C211004

100ml

C211005

500ml

Crystaldex G25

(Fine)

C214001

100g

35-140µm

C214002

500g

C214003

5kg

C214004

100ml

C214005

500ml

Crystaldex G25

(Medium)

C213001

100g

90-250µm

C213002

500g

C213003

5kg

C213004

100ml

C213005

500ml

Crystaldex G25

(Coarse)

C212001

100g

170-250µm

C212002

500g

C212003

5kg

C212004

100ml

C212005

500ml

Storage Conditions

The liquid is stored long-term in 20% ethanol at 0-30°C; the dry powder is stored long-term at 0-30°C.

Technical Specifications

Specification

Details

Matrix

Cross-linked dextran

Average Particle Size

75 µm

Particle Size Range (wet)

15-70 µm (Superfine)
40-160 µm (Fine)
90-260 µm (Medium)
170-520 µm (Coarse)

Separation Range (globular proteins)

1,000-5,000 Da

Separation Range (dextrans)

100-5,000 Da

Compatible Buffers

All standard buffer systems

Chemical Stability

Stable in:
• All common buffers
• 0.2 M NaOH
• 0.2 M HCl

pH Stability (long-term)

2-13

CIP Stability (short-term)

2-13

Storage Conditions

0.01 M NaOH, 0-30°C